Commissioning Management
Leadership and coordination of commissioning activities from pre-commissioning through energisation and operational handover, ensuring safe, efficient and timely project delivery.
Email
Established 2017 | Queensland licence 85324
Proudly Australian owned and operated
DCCOM supports utilities, industry and EPC contractors from pre-commissioning through commissioning, NSP coordination, energisation, R2 testing and handover to operations.
What DCCOM does
DCCOM provides commissioning management, primary plant testing, secondary systems protection testing, integration testing, HV switching support and GPS/R2 testing for high-voltage substations, distribution and transmission networks, power stations and renewable energy assets.
Core services
Leadership and coordination of commissioning activities from pre-commissioning through energisation and operational handover, ensuring safe, efficient and timely project delivery.
Development of management systems, management documentation, ITPs, ITRs, test procedures and SWMS to support safe, compliant and auditable project execution.
Site acceptance testing and commissioning of HV primary plant including transformers, circuit breakers, switchgear, CTs, VTs, harmonic filters, earthing systems and HV cables.
Protection relay testing, IEC 61850 integration, SCADA verification, end-to-end scheme testing and system commissioning for transmission, distribution and renewable energy assets.
HV switching, outage coordination, switching program development, NSP interface management, development of HV Operating Procedures and Safe Systems of Work, and energisation readiness support.
Management, coordination and execution of GPS / R2 compliance testing, including data acquisition and analysis support for grid compliance verification.
Technical capability
DCCOM's team works with Doble, Omicron and specialist primary plant test equipment, and has broad protection relay experience across SEL, Micom/Easergy, GE Multilin, Siemens, Reyrolle, ABB and legacy relay technologies.
HV substations and network assets up to 500 kV.
Utility-scale renewable energy commissioning and integration.
NSP Network integration of HV Assets including all enabling operational systems.
Energisation of HV and renewable energy assets, and execution of R2 Testing.
Project experience
Since DCCOM was established, the team has been responsible for commissioning management, commissioning, energisation and R2 testing across solar, BESS, substations and associated HV infrastructure.
Project recognition
"Without the unselfish commitment you bring to support all of the parties to achieve a successful outcome both projects would not have been successful."
Thomas Macneish, TEC-C Project Manager, Melbourne Renewable Energy Hub
| Project | Grid connection | Capacity | Client | NSP | State | Scope |
|---|---|---|---|---|---|---|
| Darling Downs Solar Farm | 275 kV | 108 MW | RCR | Powerlink QLD | QLD | CM, Commissioning & Energisation |
| Emerald Solar Farm | 66 kV | 72 MW | RCR | Ergon Energy | QLD | CM, Commissioning, Energisation, R2 Testing |
| Longreach Solar Farm | 66 kV | 15 MW | RCR | Ergon Energy | QLD | CM, Commissioning & Energisation |
| Oakey 1 Solar Farm | 33 kV | 25 MW | Yurika | Ergon Energy | QLD | CM, Commissioning, Energisation, R2 Testing |
| Yarranlea Solar Farm | 110 kV | 103 MW | Yurika | Ergon Energy | QLD | CM, Commissioning, Energisation, R2 Testing |
| Glenrowan Solar Farm | 66 kV | 110 MW | Yurika | AusNet | VIC | CM, Commissioning & Energisation |
| Hillston Sun Farm | 132 kV | 85 MW | Yurika/GRS | Essential Energy | NSW | CM, Commissioning, Energisation, R2 Testing |
| Bluegrass Solar Farm | 275/33 kV | 200 MW | GRS | Powerlink QLD | QLD | CM, Commissioning & Energisation |
| Molong Solar Farm | 66 kV | 25 MW | TEC-C | Transgrid | VIC | CM, Commissioning & Energisation |
| Phillip Island BESS | 22 kV | 5 MW | TEC-C | AusNet | VIC | CM, Commissioning and R2 Testing |
| Edenvale Solar Farm | 275 kV | 180 MW | Yurika/GRS | Powerlink QLD | QLD | CM, Commissioning, Energisation, R2 Testing |
| Wandoan Solar Farm | 275 kV | 125 MW | Yurika/GRS | Powerlink QLD | QLD | CM, Commissioning & Energisation |
| Wellington North Solar Farm | 330 kV | 330 MW | Yurika/GRS | Transgrid | NSW | CM, Commissioning, Energisation, R2 Testing |
| Walla Walla Solar Farm | 33 kV | 300 MW | GGC | Transgrid | NSW | CM, Commissioning, Energisation |
| Wunghnu Solar Farm | 33 kV | 75 MW | Milspec | Powercor | VIC | CM, Commissioning, Energisation |
| ANU Substations | 11 kV | - | Zinfra | - | Canberra | Commissioning |
| Deer Park Substation | 66 kV | - | TEC-C | Transgrid | VIC | CM, Commissioning |
| Terang BESS | 220 kV | 100 MW | TEC-C | AusNet | VIC | CM, Commissioning, Energisation Support |
| Melbourne Renewable Energy Hub (MREH) | 500 kV | 600 MW | TEC-C | AusNet/Transgrid (LUMEA) | VIC | CM, Commissioning, Energisation Support |
| Carwarp Solar Farm | 220 kV | 150 MW | GGC | AusNet | VIC | CM, Commissioning, Energisation, R2 Testing |
Photo case studies and selected project imagery can be added to this section as approved project photos become available.
Start a project conversation
For commissioning management, specialist testing resources, HV switching support or GPS/R2 testing, contact David Corrans.